Multi-Tenant Colocation Facility

Improving Lighting Performance Through Intelligent Controls

 

Challenge

A leading multi-tenant colocation facility sought greater lighting control across its four-story data center while reducing energy consumption and achieving a rapid return on investment. As customer occupancy and space requirements evolved, facility teams needed a more flexible way to manage lighting levels and configurations without sacrificing efficiency.
 
The existing lighting infrastructure limited flexibility and visibility. Continuing with legacy systems risked unnecessary energy consumption, higher operating costs, and added complexity when adapting spaces to changing tenant needs.
 

Solution

To support both operational and financial objectives, Mantis implemented a lighting modernization strategy centered on energy-efficient LED technology and advanced wireless controls.
 
The project followed a clear path to improved facility performance:
  1. Retrofit existing lighting with high-efficiency LED fixtures.
  2. Deploy advanced wireless controls throughout the facility.
  3. Enable occupancy sensing, daylight harvesting, and customizable lighting zones.
 
The new system provides granular control of light levels while allowing facility teams to quickly regroup and rezone fixtures through a handheld device. This flexibility helps support changing tenant layouts and operational requirements while optimizing energy performance.

Results

The upgraded lighting system improved energy efficiency, streamlined facility management, and delivered the flexibility needed to support a dynamic colocation environment. By replacing legacy infrastructure with connected controls and efficient lighting technology, the facility improved day-to-day operations while achieving meaningful financial and sustainability outcomes.
 
Performance Outcomes:
  • $40,000 in total annual savings
  • 216,800 kWh reduced annually
  • $28,000 in incentives captured
  • 151 metric tons CO₂e reduced annually
  • Less than 2 years project payback achieved
$40K

Annual Savings

216,800

kWh Saved Annually

$28K

Incentives Captured

151 MT

CO₂e Reduced

<2-Years

Project Payback

Ready to Go?

Have Questions? We’re Here to Help!

Discover more about improving facility performance while reducing costs.

Similar Case Studies

Image
Data center racks
Large‑Scale AI Data Center Developer

Enabling Power-Ready AI Infrastructure at Scale

Read More
Image
defense humvee in factory
Defense Contractor

Top defense contractor accelerated renewable energy strategy with Mantis Innovation

Read More
Image
bathroom parts aisle
Global Building Products Manufacturer

Transforming a fragmented energy approach into a cohesive, long-term strategy for cost control and stability

Read More